Coal calorific value depends on the basis on which it is measured. The calculator converts between the common bases:

  • ADB → GAR: GAR = ADB × (100 − total moisture) ÷ (100 − inherent moisture)
  • DB → GAR: GAR = DB × (100 − total moisture) ÷ 100
  • GAR → NAR: NAR ≈ GAR − 5.83 × (total moisture + 8.94 × hydrogen), in kcal/kg

The last formula subtracts the heat used to evaporate the moisture in the coal and the water formed when hydrogen burns. Units: 1 kcal/kg = 0.0041868 MJ/kg = 1.8 Btu/lb.

Why is NAR lower than GAR?

NAR (net as received) excludes the latent heat of water vapour produced during combustion. For high-moisture Indonesian coal the gap can be 400 kcal/kg or more.

Which basis is used in contracts?

South African and many Atlantic contracts use NAR; Indonesian and many Asian contracts use GAR. Laboratory reports often show ADB values.